Ask a quality engineer what a cap gauge proves and the honest answer is narrower than most inspection plans assume: it proves that certain dimensions lie between a go limit and a not-go limit. It says nothing about whether the cap will hold its shape at 200 degrees C, whether the cement will creep, or whether the flash along the thread will still be there after the first insertion. Those are separate questions with separate evidence, and confusing them is how a batch passes inspection and fails in a luminaire.
IEC 60061-1 fixes the cap dimensions and IEC 60061-3 fixes the gauges that check them, in the 7006 sheet series. A pair such as 7006-27C-1 and 7006-28A-1 on an E27 cap checks the thread against a go and a not-go limit; the not-go member is the one that catches a thread cut too deep or too shallow. Both members answer a question about the metal or the moulding at 20 degrees C, and neither knows anything about the material behind the dimension.
The boundary is worth stating plainly. A gauge decides: thread form within limits, shell diameter, contact position, overall length where a sheet covers it. A gauge does not decide: surface finish, flash, sink, weld line, cement fill, solder quality, plating thickness, or behaviour at temperature.
| Defect | Gauge verdict | Judged by |
| Flash on the thread flank | Usually passes; only blocks entry when heavy | Drawing limit and a stated viewing condition |
| Sink mark on the shell | Always passes | Cosmetic standard, not dimensional |
| Weld line across the shell | Passes unless it distorts the form | Mechanical test: torque and impact |
| Short moulding at the thread start | Caught, if the flaw reaches the go limit | Gauge, plus entry depth record |
| Ovality of the shell | Caught, by the not-go member | Gauge |
| Cement not fully cured | Invisible to the gauge | Temperature and torque test |
A limit that says clean threads with no flash is not a specification, it is an aspiration, and it will be reinterpreted differently on every shift. A workable limit is numeric and bounded in area: flash permitted up to 0.2 mm proud of the flank, and no single flash area larger than about 1 square millimetre within the first 5 mm of thread engagement. That is enough to keep a mould running and narrow enough that two inspectors reach the same verdict.
The viewing condition has to be written down as well. A defect seen at 300 mm under 500 lux is a different defect from the same one seen at 150 mm under 1000 lux. Specify the distance, the illuminance and the viewing angle, and the argument about cosmetics disappears in most audits.
Three of them account for most field returns on caps that passed inspection:
Each of these has its own article on this site, and each of them belongs in the inspection plan next to the gauge check rather than in place of it: cement creep explains the turning cap, and solder resistance covers the joint behind the contact.
The sequence that works puts the gauge first because it is fast and objective, then the cosmetic check against a written limit, then the destructive or thermal checks on a sample. Record the gauge result as a number where possible — entry depth in millimetres, not just pass — because the depth is the trend that predicts wear. Keep the cosmetic limit on the drawing the operator actually holds, not in a quality manual nobody opens.
For the artefacts themselves, the lamp cap gauge range lists the 7006 sheets against cap types so the plan can name the right pair for each cap family.