IEC 60061-3 is a collection of gauge drawings, not a prose standard. Each sheet defines one gauge, its dimensions and how it is applied. Reading the sheets correctly is the difference between buying the right gauge and buying a gauge that measures something adjacent to what the test requires.
Gauge sheets are numbered in the 7006 series, with a suffix that identifies the sheet revision and variant, for example 7006-27F-1. The number identifies the gauge, not the lamp cap. A single cap type can need several gauges: one for the thread, one for the shell diameter, one for the contact position. Never order by cap name alone; order by sheet number.
Gauge codes such as G01.01 appear in catalogue tables next to the sheet number. The code is a manufacturer's or catalogue grouping, useful for cross-reference, but the sheet number is the authoritative identifier.
A cap is acceptable when the GO gauge passes over or into the feature and the NOT GO gauge does not. On the sheets these are separate gauges, often with different masses or application forces. Three practical consequences:
Sheet dimensions are given in millimetres with tolerances, and the tolerance direction matters. A dimension marked as a maximum is a limit for the gauge, not a target. When checking a gauge:
IEC 60061 is maintained as a living document with frequent amendments. A gauge made to an older sheet may be dimensionally different from the current one, and the difference is often in the tolerance, not the nominal size. Before accepting a certificate, confirm the sheet number and revision quoted on it match the edition your test laboratory works to. This is also the reason a mixed set of gauges from different suppliers can give inconsistent verdicts on the same batch of caps.
Gauges are comparators. They work best when the operator is given a clear sequence and a place to record the verdict:
Steel gauges rust. Keep them lightly oiled, in a case, and away from the test bench where water spray and salt mist testing happens. A gauge that has been in the same room as a salt-mist chamber needs inspection before use, not a wipe with a cloth.
The product range groups lamp cap and lamp holder gauges by cap type and sheet number, and the IEC/EN 60061 equipment page lists the related test apparatus.