Reading IEC 60061-3 Gauge Sheets: 7006 Numbers, GO and NOT GO, and Tolerance Bands

Home News

Reading IEC 60061-3 Gauge Sheets: 7006 Numbers, GO and NOT GO, and Tolerance Bands

Good quality IEC/EN 60065 Standard for sales
Good quality IEC/EN 60065 Standard for sales
Our goods has safely arrived at our residence. Thank you for your excellent services. I hope we can cooperate again in the future.

—— Wira

I'm Online Chat Now
Company News
Reading IEC 60061-3 Gauge Sheets: 7006 Numbers, GO and NOT GO, and Tolerance Bands

IEC 60061-3 is a collection of gauge drawings, not a prose standard. Each sheet defines one gauge, its dimensions and how it is applied. Reading the sheets correctly is the difference between buying the right gauge and buying a gauge that measures something adjacent to what the test requires.

What the sheet number tells you

Gauge sheets are numbered in the 7006 series, with a suffix that identifies the sheet revision and variant, for example 7006-27F-1. The number identifies the gauge, not the lamp cap. A single cap type can need several gauges: one for the thread, one for the shell diameter, one for the contact position. Never order by cap name alone; order by sheet number.

Gauge codes such as G01.01 appear in catalogue tables next to the sheet number. The code is a manufacturer's or catalogue grouping, useful for cross-reference, but the sheet number is the authoritative identifier.

GO and NOT GO are separate drawings

A cap is acceptable when the GO gauge passes over or into the feature and the NOT GO gauge does not. On the sheets these are separate gauges, often with different masses or application forces. Three practical consequences:

  • A set that contains only a GO gauge cannot reject an oversize cap.
  • The application force is part of the gauge definition. Adding weight to make a tight gauge pass is not a permitted variation.
  • Wear on a GO gauge makes it accept parts that should fail. Wear on a NOT GO gauge makes it reject good parts. Both are calibration failures, in opposite directions.

Reading dimensions and tolerances

Sheet dimensions are given in millimetres with tolerances, and the tolerance direction matters. A dimension marked as a maximum is a limit for the gauge, not a target. When checking a gauge:

  1. Identify every dimension on the sheet, including those the catalogue omits for clarity.
  2. Measure at the specified temperature, normally 20 degrees C, with an instrument whose uncertainty is small compared with the tolerance.
  3. Check form as well as size: roundness of a go ring, straightness of a plug, surface finish on the gauging surface.
  4. Compare with the sheet, not with a drawing from an older edition.

Editions and revisions

IEC 60061 is maintained as a living document with frequent amendments. A gauge made to an older sheet may be dimensionally different from the current one, and the difference is often in the tolerance, not the nominal size. Before accepting a certificate, confirm the sheet number and revision quoted on it match the edition your test laboratory works to. This is also the reason a mixed set of gauges from different suppliers can give inconsistent verdicts on the same batch of caps.

Using the gauge on a production line

Gauges are comparators. They work best when the operator is given a clear sequence and a place to record the verdict:

  • Clean the gauge and the cap before checking; abrasive dust on a gauge face is a lapping compound.
  • Apply the gauge by hand, in the orientation shown on the sheet, without impact.
  • Record GO and NOT GO separately, with the gauge sheet number and the calibration due date.
  • Retire a gauge at the defined wear limit; do not "adjust" a gauge in service.

Storage and handling

Steel gauges rust. Keep them lightly oiled, in a case, and away from the test bench where water spray and salt mist testing happens. A gauge that has been in the same room as a salt-mist chamber needs inspection before use, not a wipe with a cloth.

The product range groups lamp cap and lamp holder gauges by cap type and sheet number, and the IEC/EN 60061 equipment page lists the related test apparatus.