Go Gauge Thread Depth: Where the Cap Must Stop and What Half a Millimetre Decides

Home News

Go Gauge Thread Depth: Where the Cap Must Stop and What Half a Millimetre Decides

Good quality IEC/EN 60065 Standard for sales
Good quality IEC/EN 60065 Standard for sales
Our goods has safely arrived at our residence. Thank you for your excellent services. I hope we can cooperate again in the future.

—— Wira

I'm Online Chat Now
Company News
Go Gauge Thread Depth: Where the Cap Must Stop and What Half a Millimetre Decides

Screwing a lamp into a holder is a mechanical fit with an electrical consequence. The cap has to stop at a defined depth so the centre contact meets the holder contact with the right pressure, and so the shell sits far enough in to be gripped. A thread that is dimensionally correct but cut too shallow produces a lamp that fits loosely, arcs at the centre contact and fails the temperature rise test.

The go gauge checks exactly that: not only that the thread is not too large, but that it goes in far enough to prove the thread is complete.

What the gauge checks

FeatureWhat is verifiedTypical consequence of failure
Thread formGo gauge enters to the marked depthCap jams or sits proud
Thread depthEntry to the reference plane, not just engagementCentre contact pressure too low
Major diameterNot-go gauge does not enterCap too loose in the holder
Shell diameterGo ring passes over the shellCap will not enter the holder at all
Cap lengthGo gauge depth mark level with the cap edgeContact gap or over-travel
InsulationContact not proud of the shellTouch hazard and flashover

The depth mark is the part operators ignore. A go gauge that threads in three turns and stops has told you the thread starts correctly; it has not told you the thread is complete. Only entry to the marked depth proves that, and a cap that stops short will fail in a holder even though every other dimension is right.

Why partial entry happens

Four causes, and they look identical at the gauge:

  • Incomplete thread. The die did not cut to full depth at the end of the shell, usually because the blank was short.
  • Burr at the start. A burr at the first thread prevents the gauge from starting square, so it binds after a turn.
  • Plating build-up. Nickel on the thread root reduces the effective depth, which is why plated caps are gauged after plating, not before.
  • Gauge wear. A worn go gauge threads deeper than a new one, so a cap that stopped short last month passes this month.

Gauging practice

Thread the gauge by hand, without a wrench, until it stops. Forcing it with a strap wrench proves nothing except that the gauge is stronger than the cap. Read the depth against the mark, not against the feel. Then repeat on three caps from each batch: a single cap can be an outlier, and three is enough to see a trend.

Record the depth reached, not just pass or fail. A batch that stops at 0.3 mm short is a process problem that can be corrected; a batch that stops at 1.5 mm short is scrap. That distinction only exists if the number is written down.

Keeping the gauge honest

A cap gauge is a hardened thread, and it wears on the flanks and at the entry. Check it against its drawing on a fixed schedule, and check the depth mark itself with a depth micrometer: the mark is a scribed line and it can be polished away by cleaning. A gauge without a legible mark cannot verify depth at all.

Store it on a stand, not in a drawer with other steel. A chipped entry thread is a gauge that will bind on every cap and be blamed on the product. A lamp cap go gauge with a hardened, marked thread and a certificate stating the sheet number is the minimum for a production line, and the site index lists the gauges by cap type.

Reading the depth in practice

Thread the gauge until it stops without force, then measure the gap between the gauge shoulder and the cap face with a depth micrometer. Healthy caps close that gap to within 0.2 mm of the drawing value. A gap of 0.5 mm is a warning that the last thread is incomplete; 1.5 mm is a cap that will not seat.

Check the depth on three caps from each batch and record the value in millimetres. A process that drifts from 0.1 mm to 0.4 mm over a shift is a die temperature problem, and it is visible a week before the first field failure if the numbers are written down.