An E14 cap inspection looks like a two-step process: the go gauge should enter, the not-go gauge should not. That is correct and incomplete. The pair checks two different failure modes on two different features, and a cap can pass both and still be rejected at the next stage of assembly. Understanding what each gauge is for turns a pass/fail ritual into a diagnosis.
Start with what the designation means. In IEC 60061-3 the number in an Edison screw cap is the nominal thread diameter in millimetres: an E14 thread is 14 mm across, an E27 is 27 mm, and the two differ by 13 mm in diameter. The gauge pair does not measure that diameter directly. It brackets the cap between a maximum and a minimum, and both limits are on the sheet rather than in the designation.
| Go gauge | Confirms the cap is not too large in the dimensions that must fit into a lampholder. It must enter and seat to the depth defined on the sheet. |
| Not-go gauge | Confirms the cap is not too small in the dimensions that must make contact and hold. It must not enter beyond the defined limit. |
| Both | Together they bound the cap between a maximum and a minimum, and that pair is the tolerance. |
The go gauge protects the lampholder from damage and the assembly from a cap that will not fit. The not-go gauge protects function: a cap that is too small will not hold, will not make reliable contact, and may sit too deep or too shallow.
A go gauge that enters a few turns and stops has not passed. The criterion is that the cap engages to the depth the sheet defines, which is what guarantees the cap will sit correctly in a lampholder. Two reasons a go gauge stops short even when the thread is nominally correct:
Recording how many turns were achieved before binding is more useful than a binary result. A cap that reaches 80 percent of depth consistently is a supplier tooling problem, not a random defect.
A not-go gauge is made at the minimum material condition. It must not enter the cap beyond a defined amount. If it does, the cap's internal feature is too large or too deep, which is the opposite of what the go gauge checks.
The failure this catches is a cap that fits loosely: it will assemble, it will often light, and it will fail in service through poor contact or through working loose. A 0.02 mm reduction in thread diameter is enough to turn a firm fit into a loose one, which is why the not-go side of the pair is not optional. This is the defect that a visual inspection cannot find and that only a not-go gauge detects.
Contact position and insulation are checked by separate gauges, and this is where a cap that passed the go/not-go pair can still be rejected:
A gauge room that only holds the go/not-go pair is testing the thread and calling it a cap inspection.
A production line usually needs 3 gauges for one cap: go, not-go and contact-making. Running only the first 2 tests the thread in 2 directions and leaves the electrical interface unmeasured, which is why a cap that passes inspection can still fail on the assembly line.
Three outcomes are worth separating in a record, because they point at different fixes:
The lamp cap gauge range lists E14 go, not-go and contact-making gauges by sheet number; the catalogue indexes the matching lampholder gauges.