A lampholder gauge set usually contains more gauges than anyone uses. The thread go and no-go gauges get all the attention, because a thread that does not fit is an obvious failure. The contact-making gauge sits in the box and is used when a customer complains that a lamp does not light.
It checks the position of the contact in the base of the holder, relative to the thread datum. A lamp cap has a contact at its tip; when the cap is screwed fully home, that tip must press on the holder contact with enough travel to ensure a reliable connection.
The gauge simulates a lamp cap that is at the limit of the permitted dimensions, and it does two things at once: it confirms the contact is not too deep, which would mean no touch at all, and it confirms the contact is not so proud that it is over-compressed when a nominal cap is fitted.
The thread gauges index on the thread. The contact-making gauge indexes on the thread as well, because the thread is the datum. But what it measures is a distance from that datum to a sprung part, and that part moves.
That is the difficult part. The holder contact is usually a spring or a bent strip, and its free height depends on how it was formed and how many lamps it has already accepted. A gauge that is pushed in once measures the spring at rest; a holder that has taken a thousand lamps has a spring that has taken a set.
| Gauge | What it establishes | What it cannot |
|---|---|---|
| thread go | thread not too tight | contact position |
| thread no-go | thread not too loose | contact spring force |
| contact-making | contact reaches a cap at limits | long-term spring life |
Contact too deep. The lamp screws in fully and the tip does not touch. The holder looks perfect, the lamp looks perfect, and the circuit is open. This is the failure that generates returns, because the customer can see nothing wrong.
Contact too proud. The contact stands so high that the lamp cap cannot reach the fully-seated position, or it does so only under force. The lamp may light, but the cap sits proud of the holder skirt, which is both a thermal problem and, on a holder with a shade ring, a mechanical one.
Both are dimensional, and both are produced by the same thing: the depth to which the contact is inserted or the height to which it is bent during assembly.
Three rules, all of which are habit rather than skill:
Do not force it. The gauge is at the limit of the permitted cap dimensions. If it needs force, the holder is at or beyond that limit, which is a finding, not an obstacle.
Read it on the first insertion. A holder that has just been assembled has its contact at free height. Inserting the gauge twice lowers the reading, and the second reading is the one that looks better.
Check several orientations. A screw-base contact that is a bent strip can be at a different height on one side than the other. Rotating the gauge 180 degrees and repeating finds contacts that are tilted rather than low.
The contact-making gauge has a small, hard, protruding pin, and that pin takes the whole load of every insertion. On a gauge used daily it wears, and a worn pin reads a contact as too proud.
A pin that has been bent is worse: a bent pin still enters, but it contacts the holder contact off-centre, so the insertion depth no longer represents the cap tip position. The bend is usually a few tenths of a millimetre and invisible without a straightedge.
Inspect the pin for straightness and for a rounded tip at every calibration, and record the protrusion length of the pin. It is the only dimension on the gauge that changes through use.
IEC 60061-3 carries the gauge drawings, and each gauge is a standard sheet with its own tolerances. The dimensions are not transferable between cap sizes: an E27 gauge is not an E26 gauge with a different label, and using one for the other produces a result that means nothing.
The practical discipline is to keep the gauge with its sheet, and to check the sheet number on the gauge against the cap designation being produced. A mixed box of gauges is a box where someone will eventually pick the wrong one.
Gauge identification and standard sheet, the result on first insertion, and the orientation if more than one was tested. A record that says "contact OK" cannot distinguish a holder that was checked once from one that was checked in four positions, and the difference shows up as a field failure rate that nobody can explain.