B22 Bayonet Gauge: The Three Pins That Have to Agree at Once

Home News

B22 Bayonet Gauge: The Three Pins That Have to Agree at Once

Good quality IEC/EN 60065 Standard for sales
Good quality IEC/EN 60065 Standard for sales
Our goods has safely arrived at our residence. Thank you for your excellent services. I hope we can cooperate again in the future.

—— Wira

I'm Online Chat Now
Company News
B22 Bayonet Gauge: The Three Pins That Have to Agree at Once

A screw cap is defined by one thing: its thread. A bayonet cap is defined by three: two side pins and the position of the cap relative to them. That difference is why B22 gauging is harder than E27, and why a set of single-feature gauges can miss the failure that matters.

The three locating features

FeatureWhat it controlsFailure in service
pin diameterengagement in the holder slotloose fit, poor contact
pin position (height and spacing)how far the cap seatscap does not seat, or sits too deep
contact positionelectrical contact with the holderintermittent lamp, arcing

Why separate gauges are not enough

A pin diameter gauge confirms each pin is the right size. A height gauge confirms each pin sits at the right distance from the cap face. Both can pass while the cap refuses to seat, because the third variable — the angular position of the pins relative to each other, and to the cap axis — is wrong.

That error only appears in combination. Two pins each within tolerance, but set 2 degrees apart from where they should be, produce a cap that jams halfway into the holder. No single-feature gauge detects it.

The combination gauge and how to use it

The combination gauge carries all three features at once: two slots for the pins and a datum face for the cap. If the cap enters and seats, all three features are simultaneously correct.

This is a go-only check in most designs, which means it carries no wear allowance and should be inspected more often than a go plug. A combination gauge that has worn at a slot will accept a cap with mispositioned pins, and the failure will look intermittent because it depends on how the cap is presented.

Checking the combination gauge

Three checks, all quick:

Slot width. Measure at two depths. A slot that is wider at the entry than at the bottom lets a misaligned pin start and then bind, producing a fail that looks like a product problem.

Slot angular position. The relative angle between the two slots is the feature that catches the error single gauges miss. It is also the feature most likely to be damaged by a dropped gauge.

Datum face flatness. A face with a burr holds the cap off, so it seats shallow and the check reports a fail that does not exist. A face with a dent lets it seat deep.

Reading a rejection

A cap that will not enter the combination gauge at all usually has a pin that is too large or badly positioned. A cap that enters halfway and jams has the pins in the wrong angular relationship.

A cap that seats but feels loose has pins that are undersized or slots that have worn — in the second case the gauge, not the cap, is suspect.

What the record needs

Which gauge, the gauge number, how far the cap entered (a measurement, not a description), and a photograph. For bayonet caps the entry depth is the most informative field, because it distinguishes the failure modes better than a pass/fail verdict.

A record that says only "B22 rejected" cannot support a decision about whether to adjust the mould or to quarantine the batch.

Pub Time : 2026-11-24 09:00:00 >> News list
Contact Details
SHENZHEN JULIXING INSTRUMENTS CO., LTD.

Contact Person: Mr. Eason Wang

Tel: 86-755-33168386

Fax: 86-755-61605199

Send your inquiry directly to us (0 / 3000)